Special Panel Zone Entries - Certain specialized Panel Zones must exist for each Communicator Format to identify special circumstances.
Because each Communicator Format has its own (somewhat) unique set of Panel Zones representing almost all of the Alarm Signals and Events that will be transmitted by that type of Communicator Format, each of these Communicator Formats must also have all of the specialized Panel Zones that are listed below:
Panel Zones -  The Panel Zones required for each Communicator Format are as follows:
Signal ID = A105        Alarm Code = System Messages        OCTAR = Alarm        Description = Runaway alarm (Received too many signal in a  short time period)
Signal ID = A107        Alarm Code = System Messages        OCTAR = Alarm        Description = No CSID or SI on Alarm Signal
Signal ID = A108        Alarm Code = System Messages        OCTAR = Alarm        Description = Invalid Caller ID (Phone number not in CSID caller list)
oThree Signal ID = A108 records must be entered with the following Physical Zones and Descriptions:

 

Physical Zone

Descriptions (add this text to above "Invalid Caller ID" message

0

There is no phone in the subscriber panel

1

There is at least one phone number in the panel

2

There is no account with that CSID

Or the account is offline

Or the subscriber is a deleted account (Old Subscriber = ‘T’)

 

Signal ID = A121        Alarm Code = System Messages        OCTAR = Alarm        Description = Manual Customer Note
Signal ID = A127        Alarm Code = System Messages        OCTAR = Alarm        Description = Invalid SIA package or Unable to process SIA package
Signal ID = A128        Alarm Code = System Messages        OCTAR = Alarm        Description = Temp Note Added/Modified/Deleted
Signal ID = A130        Alarm Code = System Messages        OCTAR = Alarm        Description = Account canceled via Dealer Client or Millennium
Signal ID = A131        Alarm Code = System Messages        OCTAR = Alarm        Description = Account set to offline
Signal ID = A132        Alarm Code = System Messages        OCTAR = Alarm        Description = Account set to online